JET PUMP TROUBLESHOOTING
 

B - MOTOR OVERHEATS AND OVERLOAD TRIPS OUT

CAUSE OF TROUBLE HOW TO CHECK HOW TO CORRECT
Incorrect line voltage
 
Use voltmeter to check at pressure switch or terminals nearest pump If voltage under recommended minimum, check size of wiring from main switch on property. If OK, contact power company
Motor wired incorrectly Check motor wiring diagram
 
Reconnect for proper voltage as per wiring diagram
Inadequate ventilation Check air temperature where pump is located. If over 100ºF overload may be tripping on external heat Provide adequate ventilation or move pump
 
Prolonged low pressure delivery
 
Continuous operation at very low pressure places heavy overload on pump. This can cause overload protection to trip Install globe valve on discharge line and throttle to increase pressure
 